demo_tlineP
1.
Symbol:

1.
Demo kit Transmission Line:
a)
Parameters:
|
Name |
Description |
Unit |
Default |
|
Type |
Type of transmission line(M0, M1, M2 or
M1+M2) |
nil |
M1 |
|
Width(w) |
Width of the transmission line |
um |
20 |
|
Length |
Length of the transmission line |
um |
100 |
|
Inductance |
Associated
inductance of the transmission line |
pH |
41.924 |
|
Offset1 |
offset
at pin 1, for Thick metal only |
nil |
None |
|
Offset2 |
offset
at pin 2, for Thick metal only |
nil |
None |
b)
Range:
Type0 (M0) ; M0 transmission line ; Width, w=(5 to 50 um) ; Length, l = 5um to
infinity
Type1 (M1) ; M1 transmission line ; Width, w=(5 to 50 um) ; Length, l = 5um to infinity
Type2 (M2) ; M2 transmission line ; Width, w=(5 to 50 um) ; Length, l = 5um to infinity
Type3 (M1+M2) ; M1+M2 transmission line ; Width, w=(5 to 50 um) ; Length, l = 5um to infinity
2.
Notes:
a)
These
transmission lines are based on schematic MLIN models (with proper MSUB
definitions).
b)
For
general inter connections, use either Type 1 or Type 2 lines. Type 3 lines
carry higher current (as their thickness is more).
c)
Type
0 line is generally used to connect capacitors.
d)
Available
both in schematic and layout with synchronization.
3.
Model accuracies:
Type = tline1; Width, w = 10 um ; Length, l =
150 um ; Inductance = 90.9099pH
At 20 GHz the Phase difference is 4.677 degrees.

4. Cross-section Views:


The
cross section views given above are not to scale.