demo_clinP

            

1.   Symbol:

 

 

 

 

 

 

1.   Demo kit Coupled Lines:

 

a)     Parameters:

 

Name

Description

Unit

Default

Type

Type of transmission line(M0, M1, M2 or M1+M2)

nil

M1

w

Width of the transmission line

um

20

l

Length of the transmission line

um

100

w1

Width of line that connects to pin 1

um

0

w2

Width of line that connects to pin 1

um

0

w3

Width of line that connects to pin 1

um

0

w4

Width of line that connects to pin 1

um

0

offset1

offset at pin 1, for Thick metal only;(Extend, None, Recess)

nil

None

offset2

offset at pin 2, for Thick metal only ;(Extend, None, Recess)

nil

None

offset3

offset at pin 3, for Thick metal only ;(Extend, None, Recess)

nil

None

offset4

offset at pin 3, for Thick metal only ;(Extend, None, Recess)

nil

None

 

b)    Range:      

                  Type0 (M0) ;           M0 coupled line  ; Width, w=(5 to 50 um) ; Length, l = 5um to infinity ; w1, w2, w3 and w4 = (0 to 150 um)

                  Type1 (M1) ;           M1 coupled line  ; Width, w=(5 to 50 um) ; Length, l =   5um to infinity ; w1, w2, w3 and w4 = (0 to 150 um)

                  Type2 (M2) ;           M2 coupled line  ; Width, w=(5 to 50 um) ; Length, l =   5um to infinity ; w1, w2, w3 and w4 = (0 to 150 um)

                  Type3 (M1+M2) ;     M1+M2 coupled line  ; Width, w=(5 to 50 um) ; Length, l =  5um to infinity ; w1, w2, w3 and w4 = (0 to 150 um)     

 

2.   Notes:

 

a)     These coupled lines are based on schematic MCLIN models (with proper MSUB definitions).

b)    For general inter connections, use either Type 1 or Type 2 coupled lines. Type 3 coupled lines carry higher current (as their thickness is more).

c)     Type 0 coupled line is generally used to connect capacitors.

d)    Available both in schematic and layout with synchronization.